home *** CD-ROM | disk | FTP | other *** search
/ IBM OEM Software Product … CD For PC Manufacturers / IBM OEM Software - Product Sampler CD for PC Manufacturers.iso / InternetIntranets / Notes / LOTUS027.DSK / MODEMS / MHZ144R.MDM < prev    next >
Text File  |  1994-11-23  |  5KB  |  190 lines

  1. ; Megahertz  P2144 w/Rockwell chipset
  2.  
  3. ; Last revision 11/23/94 (update this date each time
  4. ; you edit);  it is also advisable to rename
  5. ; your edited file [use Save As, rather than Save 
  6. ; option] to avoid later confusion and to keep the 
  7. ; original .MDM file intact).
  8.  
  9. ; NOTE: Refer to the file TEMPLATE.MDM (A Sample Modem 
  10. ; Command File) for a description of modem command 
  11. ; files and how they work. "A Sample Modem Command 
  12. ; File" is user selectable within the Lotus Notes 
  13. ; Setup dialog "Modem Type" listbox in which you found 
  14. ; this modem command file (see end of listings, 
  15. ; beginning with a period) and is a printable ASCII 
  16. ; text file (approximately 14 pages). 
  17.  
  18. ; Additional information may be obtained from either of 
  19. ; the two so-called "generic" modem command files 
  20. ; (alphabetically listed under letter G, designed for 
  21. ; use with Notes Releases 2.x and 3.x, 9600 bps and 
  22. ; 14400 bps maximum, respectively), each of which may 
  23. ; first be tried as-is with unlisted modems, then edited 
  24. ; if required (within the Notes edit box, or outside of 
  25. ; Notes, with any text editor) according to the printed 
  26. ; instructions within each file, and in compliance with 
  27. ; the vendor's command set, result codes, DIP switch 
  28. ; settings, and technical specifications as listed in 
  29. ; the equipment's users manual.
  30.  
  31. ; NOTE: This modem accepts command strings of 48 or 
  32. ; fewer characters.  
  33.  
  34. ; For the specific modem(s) listed under this heading:
  35. ;===========================================
  36.  
  37. [attributes]
  38.  
  39. MODELS=Megahertz P2144 w/Rockwell chipset
  40. NULL MODEM =0
  41. MAXIMUM SPEED=57600
  42. DEFAULT SPEED=57600
  43.  
  44. [commands]
  45.  
  46. ESCAPE=+++
  47.  
  48. ATTENTION=ATE0V1
  49.  
  50. HANGUP=ATH0
  51.  
  52. SETUP=AT&F1
  53. SETUP=ATE0V1
  54. SETUP=ATQ0W1&C1&D2E0\\N1S0=0S7=60X4
  55.  
  56. RTS/CTS ENABLED=AT&K3
  57. RTS/CTS IGNORED=AT&K0
  58.  
  59. VOLUME OFF=ATM0
  60. VOLUME LOW=ATM1L1
  61. VOLUME MEDIUM=ATM1L2
  62. VOLUME HIGH=ATM1L3
  63.  
  64. ANSWER=ATA
  65.  
  66. MANUAL DIAL=ATX3S9=1D
  67. AUTO DIAL SETUP=ATS9=6
  68.  
  69. AUTO PULSE DIAL=ATDP
  70. AUTO TONE DIAL=ATDT
  71.  
  72. AUTO DIAL SUFFIX=,
  73.  
  74.  
  75. [responses]
  76.  
  77. OK=OK
  78.  
  79. RING=RING
  80.  
  81. NO CARRIER=NO CARRIER
  82.  
  83. ERROR=ERROR
  84.  
  85. NO DIALTONE=NO DIALTONE
  86.  
  87. BUSY=BUSY
  88.  
  89. NO ANSWER=NO ANSWER
  90. CONNECT, 57600, 57600=CONNECT 57600
  91. CONNECT, 57600, 57600=CONNECT 57600*
  92. CONNECT, 57600, 57600=CONNECT 57.6*
  93. CONNECT, 57600, 57600=CONNECT 57*
  94.  
  95. CONNECT, 57600, 38400=CONNECT 38400
  96. CONNECT, 57600, 38400=CONNECT 38400*
  97. CONNECT, 57600, 38400=CONNECT 38.4*
  98. CONNECT, 57600, 38400=CONNECT 38*
  99.  
  100. CONNECT, 57600, 28800=CONNECT 28800
  101. CONNECT, 57600, 28800=CONNECT 28800*
  102. CONNECT, 57600, 28800=CONNECT 28.8*
  103. CONNECT, 57600, 28800=CONNECT 28*
  104.  
  105. CONNECT, 57600, 26400=CONNECT 26400
  106. CONNECT, 57600, 26400=CONNECT 26400*
  107. CONNECT, 57600, 26400=CONNECT 26.4*
  108. CONNECT, 57600, 26400=CONNECT 26*
  109.  
  110. CONNECT, 57600, 24000=CONNECT 24000
  111. CONNECT, 57600, 24000=CONNECT 24000*
  112. CONNECT, 57600, 24000=CONNECT 24.0*
  113. CONNECT, 57600, 24000=CONNECT 24*
  114.  
  115. CONNECT, 57600, 21600=CONNECT 21600
  116. CONNECT, 57600, 21600=CONNECT 21600*
  117. CONNECT, 57600, 21600=CONNECT 21.6*
  118. CONNECT, 57600, 21600=CONNECT 21*
  119.  
  120. CONNECT, 57600, 19200=CONNECT 19200
  121. CONNECT, 57600, 19200=CONNECT 19200*
  122. CONNECT, 57600, 19200=CONNECT 19.2*
  123. CONNECT, 57600, 19200=CONNECT 19*
  124.  
  125. CONNECT, 57600, 16800=CONNECT 16800
  126. CONNECT, 57600, 16800=CONNECT 16800*
  127. CONNECT, 57600, 16800=CONNECT 16.8*
  128. CONNECT, 57600, 16800=CONNECT 16*
  129.  
  130. CONNECT, 57600, 14400=CONNECT 14400
  131. CONNECT, 57600, 14400=CONNECT 14400*
  132. CONNECT, 57600, 14400=CONNECT 14.4*
  133. CONNECT, 57600, 14400=CONNECT 14*
  134.  
  135. CONNECT, 57600, 12000=CONNECT 12000
  136. CONNECT, 57600, 12000=CONNECT 12000*
  137. CONNECT, 57600, 12000=CONNECT 12.0*
  138. CONNECT, 57600, 12000=CONNECT 12*
  139.  
  140. CONNECT,  9600, 9600=CONNECT 9600
  141. CONNECT, 57600, 9600=CONNECT 9600*
  142. CONNECT, 57600, 9600=CONNECT 9.6*
  143. CONNECT, 57600, 9600=CONNECT 96*
  144.  
  145. CONNECT,  7200, 7200=CONNECT 7200
  146. CONNECT, 57600, 7200=CONNECT 7200*
  147. CONNECT, 57600, 7200=CONNECT 7.2*
  148. CONNECT, 57600, 7200=CONNECT 72*
  149.  
  150. CONNECT,  4800, 4800=CONNECT 4800
  151. CONNECT, 57600, 4800=CONNECT 4800*
  152. CONNECT, 57600, 4800=CONNECT 4.8*
  153. CONNECT, 57600, 4800=CONNECT 48*
  154.  
  155. CONNECT,  2400, 2400=CONNECT 2400
  156. CONNECT, 57600, 2400=CONNECT 2400*
  157. CONNECT, 57600, 2400=CONNECT 2.4*
  158. CONNECT, 57600, 2400=CONNECT 24*
  159.  
  160. CONNECT,  1200, 1200=CONNECT 1200
  161. CONNECT, 57600, 1200=CONNECT 1200*
  162. CONNECT, 57600, 1200=CONNECT 1.2*
  163.  
  164. CARRIER,,28800=CARRIER 28800
  165.  
  166. CARRIER,,26400=CARRIER 26400
  167.  
  168. CARRIER,,24000=CARRIER 24000
  169.  
  170. CARRIER,,21600=CARRIER 21600
  171.  
  172. CARRIER,,19200=CARRIER 19200
  173.  
  174. CARRIER,,16800=CARRIER 16800
  175.  
  176. CARRIER,,14400=CARRIER 14400
  177.  
  178. CARRIER,,12000=CARRIER 12000
  179.  
  180. CARRIER,, 9600=CARRIER 9600
  181.  
  182. CARRIER,, 7200=CARRIER 7200
  183.  
  184. CARRIER,, 4800=CARRIER 4800
  185.  
  186. CARRIER,, 2400=CARRIER 2400
  187.  